8
8
8-65
8-65
Service Mode > COPIER > ADJUST > DENS
Service Mode > COPIER > ADJUST > DENS
COPIER>ADJUST>DENS
CONT-M
ATR Sensor (M) control voltage entry
Lv.1 Details
To enter the density detection control voltage of the ATR Sensor (M).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after clearing
of the data
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-M/4).
Display/adj/set range 0 to 255
Default value
120 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-M/4
CONT-C
ATR Sensor (C) control voltage entry
Lv.1 Details
To enter the density detection control voltage of the ATR Sensor (C).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after clearing
of the data
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-C/4).
Display/adj/set range 0 to 255
Default value
120 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-C/4
CONT-K
ATR Sensor (Bk) control voltage entry
Lv.1 Details
To enter the density detection control voltage of the ATR Sensor (Bk).
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after clearing
of the data
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
The value changes if the Developing Unit is initialized (INISET-K/4).
Display/adj/set range 0 to 255
Default value
120 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-K/4
COPIER>ADJUST>DENS
D-Y-LVL
Entry of ATR patch Y-clr correction VL
Lv.1 Details
To enter the Y-color correction value of ATR patch.
The value is determined whenever the Developing Unit (Y) is initialized.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after the
processing is done
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
When INISET-Y is executed, the value is rewritten.
Display/adj/set range -50 to 50
Default value
0 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y
D-M-LVL
Entry of ATR patch M-clr correction VL
Lv.1 Details
To enter the M-color correction value of ATR patch.
The value is determined whenever the Developing Unit (M) is
initialized.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after the
processing is done
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
When INISET-M is executed, the value is rewritten.
Display/adj/set range -50 to 50
Default value
0 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-M
D-C-LVL
Entry of ATR patch C-clr correction VL
Lv.1 Details
To enter the C-color correction value of ATR patch.
The value is determined whenever the Developing Unit (C) is
initialized.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after the
processing is done
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
OK key.
Caution
When INISET-C is executed, the value is rewritten.
Display/adj/set range -50 to 50
Default value
0 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-C