8
8
8-130
8-130
Service Mode > COPIER > FUNCTION > DBG-LOG
Service Mode > COPIER > FUNCTION > DBG-LOG
COPIER>FUNCTION>SYSTEM
RSRAMBUP
Backup of Reader setting data
Lv.2 Details
To back up setting data of the Reader in the Scanner Unit memory to
the HDD.
Use case
When clearing setting data of the Reader at the time of troubleshooting
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period of
time is restored, it is overwritten with the old setting data and the new
data is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode COPIER> FUNCTION> SYSTEM> RSRAMRES
RSRAMRES
Restoration of Reader set data
Lv.2 Details
To restore the setting data of the Reader which has been backed up in
the HDD to the Scanner Unit memory.
Use case
When clearing setting data of the Reader at the time of troubleshooting
Adj/set/operate method Select the item, and then press OK key.
Caution
During operation, the setting data changes by manual or automatic
adjustment. When backup data which has been left for a long period of
time is restored, it is overwritten with the old setting data and the new
data is deleted.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode COPIER> FUNCTION> SYSTEM> RSRAMBUP
R-REBOOT
Reboot of host machine: remote
Lv.1 Details
To reboot the host machine by remote control (using VNC).
Use case
When rebooting the host machine by remote control
Adj/set/operate method Select the item, and then press OK key.
T-8-43
■
DBG-LOG
COPIER>FUNCTION>DBG-LOG
LOG2USB
Storage of debug log to USB memory
Lv.2 Details
To store a set of debug logs to the USB memory at the error
occurrence.
A type of log to be collected is set in LOG-TRIG.
If there is a debug log which has been automatically saved, it is
archived at this time.
Required time differs according to the device conditions and volume of
log data.
Use case
When analyzing the cause of a problem
Adj/set/operate method 1) Install the USB memory.
2) Select the item, and then press OK key.
Caution
- Wait until the machine recognizes the USB memory (approx. 10
sec.).
- During the data transfer (“ACTIVE” display), do not turn OFF the
power/remove the USB memory/use the screen for operations.
Display/adj/set range
During operation: ACTIVE, At normal termination: OK!, At abnormal
termination: NG
Related service mode COPIER> FUNCTION> DBG-LOG> LOG-TRIG
LOG2SRVR
For R&D
LOG-TRIG
Setting of debug log save conditions
Lv.2 Details
To set the conditions (timing, types, etc.) to automatically save the
debug logs (stored as an archive file).
The conditions written in the file are set by reading the operation
setting file of the setting value from the Main Controller.
When setting a new condition is necessary, read the operation setting
file provided by R&D from the USB memory.
Use case
- When changing the conditions for automatic save of debug logs
- When setting a new condition
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 99999
Related service mode COPIER> FUNCTION> DBG-LOG> LOG2USB, LOG2SRVR
HIT-STS
Display of debug log state
Lv.2 Details
To display whether archive file of the debug log which is matched with
the conditions set in LOG-TRIG exists or not.
Use case
When checking the debug log automatically saved
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
When an automatically stored log exists: OK, When no automatically
stored log exists: --
Related service mode COPIER> FUNCTION> DBG-LOG> LOG-TRIG
SYSLOG
For R&D