Technical Explanation > Embedded RDS > E-RDS Setup > Steps to Service Browser settings
Technical Explanation > Embedded RDS > E-RDS Setup > Steps to Service Browser settings
3) Enable E-RDS function and execute communication test.
(a) Select COPIER > Function > INSTALL > E-RDS.
(b) Press the numeric key [1] on the control panel (the setting value is changed to 1) and
touch the [OK] button. (The data is reflected to the setting value field.)
CAUTION:
The following settings i.e. RGW-PORT and RGW-ADR in Service mode must not be
change unless there are specific instructions to do so.
Changing these values will cause error in communication with UGW.
NOTE:
This initiates the communication test between the device and the UGW.
4) Select [COM-TEST] and then touch [OK].
The communication test with UGW will be executed.
If the communication is successful, "OK!" is displayed. If "NG!" (failed) appears, refer to the
"Troubleshooting" and repeat until "OK!" is displayed.
NOTE:
The communication results with UGW can be distinguished by referring to the COM-
LOG. By performing the communication test with UGW, E-RDS acquires schedule
information and starts monitoring and meter reads operation.
F-2-180
■
Steps to Service Browser settings
1) In the following service modes, enable a service browser.
Select COPIER > Function > INSTALL > BRWS-ACT and then touch [OK].
NOTE:
When the status of the service browser is changed to enabled, E-RDS sends the
browser information to the UGW at this timing.
If the connection is established with UGW successfully, "OK!" is displayed. When "NG!" is
displayed, perform the steps referring to "Troubleshooting" until connection is established
with UGW.
2) Turn OFF and then ON the main power of this machine.
3) Make sure that "1 (: ACTIVE)" is set under COPIER > Display > USER > BRWS-STS.
4) When the above-shown setting values are enabled, [Service Browser] is displayed in the
Service Mode screen.
NOTE:
Generally, once service browsing is enabled, to stop the service browsing, execute
BRWS-ACT again, turn OFF and then ON the main power of this machine.
F-2-181