2
2
2-62
2-62
Technical Explanation > Fixing System > Controls > Print Temperature Control
Technical Explanation > Fixing System > Controls > Print Temperature Control
Target temperature during printing <when paper width exceeds 300 mm>
Paper type
Paper weight
(g/m
2
)
Paper Width
(mm)
Resolution
(dpi)
Fixing
speed
(mm/s)
Target temperature
(deg C)
Color
B/W
Thin paper
52 to 63
300.1 +
600 / 1200
59.7
140 to 175
Plain paper 1
64 to 75
143 to 180
Plain paper 2
76 to 90
146 to 185
Plain paper 3
91 to 105
150 to 190
Recycled paper 1
64 to 75
143 to 180
Recycled paper 2
76 to 90
146 to 185
Recycled paper 3
91 to 105
150 to 190
Color paper
64 to 82
143 to 180
Tracing paper
64 to 99
146 to 185
Pre-punched paper
64 to 75
Bond paper
83 to 99
Heavy paper 1
1-Sided Coated 1
2-Sided Coated 1
106 to 128
300.1 to 305.0
162 to 192
305.0 +
165 to 195
Heavy paper 2
1-Sided Coated 2
2-Sided Coated 2
129 to 163
300.1 to 305.0
169 to 199
305.0 +
172 to 202
Heavy paper 3
1-Sided Coated 3
2-Sided Coated 3
Label paper
164 to 220
300.1 +
175 to 205
305.1 +
184 to 212
Heavy paper 4
221 to 256
300.1 +
183 to 213
305.1 +
192 to 220
●
Paper Interval Temperature Control
The paper interval temperature is decreased to prevent temperature increase when the paper
interval becomes wider than a normal condition
*1
.
Paper Interval Temperature = Target temperature during printing - (25 to 50 deg C)
*2
*1 During down sequence
• During auto 2-sided mode
• During small-size mode
• At execution of controls (ATR control, registration control, ATVC control)
*2 Determined by the elapsed time since the previous fixing temperature control (including
standby control) and the fixing temperature when startup control started.
T-2-46
Related Service Mode:
• Display of Thermistor detection temperature
(Lv.1) COPIER > DISPLAY > ANALOG
> FIX-E (To display the center temperature of the Fixing Heater detected by the Main
Thermistor)
> FIX-E2 (To display the front edge temperature of the Fixing Heater detected by the Sub
Thermistor 1)
> FIX-E3 (To display the rear edge temperature of the Fixing Heater detected by the Sub
Thermistor 2)
• Setting of fixing temperature control temperature
(Lv.1)COPIER > OPTION > CUSTOM > TEMP-TBL (Plain paper 1, Color paper)
(Lv.1)COPIER > OPTION > IMG-FIX
> TMP-TBL2 (Heavy paper 1)
> TMP-TBL3 (Heavy paper 2)
> TMP-TBL4 (Heavy paper 3)
> TMP-TBL5 (Thin paper)
> TMP-TBL6 (Envelope)
> TMP-TBL7 (Plain paper 2, Tracing paper, Pre-punched paper)
> TMP-TBL8 (Transparency)
> TMP-TBL9 (coated paper 1)
> TMP-TB10 (coated paper 2)
> TMP-TB11 (Recycled paper 1)
> TMP-TB12 (Plain paper 3)
> TMP-TB13 (Recycled paper 2)
> TMP-TB17 (Recycled paper 3)
> TMP-TB18 (coated paper 3)
> TMP-TB19 (Heavy paper 4)
> TMP-TB20(Paper width 300.1 mm to 320 mm: Plain paper, Recycled paper, Thin paper,
Color paper, Tracing paper, Pre-punched paper, Bond paper)
> TMP-TB21 (Paper width 300.1mm to 305 mm: Heavy paper, Coated paper, Label paper)
> TMP-TB22 (Paper width 305.1 mm to 320 mm: Heavy paper, Coated paper, Label
paper)
> TMP-TB23 (Half-Speed time: Plain paper, Recycled paper, Thin paper, Color paper,
Tracing paper, Pre-punched paper, Bond paper)
<Setting Value>
-3 : -15 deg C
*1
-2 : -10 deg C
-1 : -5 deg C
0: 0 deg C [default]
+1 : +5 deg C
+2 : +10 deg C
*1. This setting is only available for TMP-TB11 (Recycled paper 1).