8
8
8-124
8-124
Service Mode > COPIER > FUNCTION > CLEAR
Service Mode > COPIER > FUNCTION > CLEAR
COPIER>FUNCTION>CLEAR
ADRS-BK
Clearing of address book
Lv.1 Details
To clear the address book data.
Use case
When clearing the address book data
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The address book data is cleared after the main power switch is turned
OFF/ON.
CNT-MCON
Clear of Main Controller service counter
Lv.1 Details
To clear the service counter counted by the Main Controller PCB.
Use case
When clearing the service counter counted by the Main Controller PCB
Adj/set/operate method Select the item, and then press OK key.
Related service mode COPIER> COUNTER
Supplement/memo
See COUNTER for the target counter.
CNT-DCON
Clear of DC Controller service counter
Lv.1 Details
To clear the service counter counted by the DC Controller PCB.
Use case
When clearing the service counter counted by the DC Controller PCB
Adj/set/operate method Select the item, and then press OK key.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
MMI
Clear Settings/Registration menu set VL
Lv.1 Details
To clear the setting values in Settings/Registration menu.
- Preferences (excluding Paper Type Management Settings)
- Adjustment/Maintenance
- Function Settings
- Set Destination (excluding Address Lists)
- Management Settings (excluding Department ID Management
Information)
Use case
When clearing various setting values in Settings/Registration menu
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The setting values are cleared after the main power switch is turned
OFF/ON.
MN-CON
Deletion of setting values
Lv.1 Details
To delete the setting values of address lists, forwarding settings,
Settings/Registration and service mode.
For details, refer to "Backup Data List" in the Service Manual.
Use case
When initializing the setting values
Adj/set/operate method 1) Select the item, and then press OK key.
The machine is automatically rebooted.
2) Turn OFF/ON the main power switch.
Caution
- Output the service mode setting values by P-PRINT before execution.
After execution, enter necessary setting value.
- RAM data is cleared after the main power switch is turned OFF/ON.
- If this item is executed while a login application other than Default
Authentication is activated, any symptom occurs. (e.g. The login screen
is not displayed.) In this case, switch the login application to Default
Authentication once.
Related service mode COPIER> FUNCTION> MISC-P> P-PRINT
COPIER>FUNCTION>CLEAR
CARD
Clearing of card ID-related data
Lv.1 Details
To clear the data related to the card ID (department).
Use case
When clearing the data related to the card ID
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The data is cleared after the main power switch is turned OFF/ON.
The login screen is displayed immediately after start-up. To display the
main menu at start-up, select "Display if function is selected" in "Login
Screen Display Settings" in Settings/Registration menu.
Display/adj/set range
During operation: ACTIVE, When operation finished normally: OK!
Related service mode COPIER> FUNCTION> INSTALL> CARD
Related user mode
Management Settings> User Management> Authentication
Management> Login Screen Display Settings
ALARM
Clearing of alarm log
Lv.1 Details
To clear the alarm logs (COPIER> DISPLAY> ALARM-2, ALARM-3).
Use case
When clearing alarm logs
Adj/set/operate method 1) Select the item, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
The alarm logs are cleared after the main power switch is turned OFF/
ON.
Related service mode COPIER> DISPLAY> ALARM-2, ALARM-3
CA-KEY
Init of key pair, certificate and CRL
Lv.2 Details
To delete the key pair, certificate and CRL collectively which are
additionally registered by the user and return to the initial state.
Use case
When a service person replaces/discards the device
Adj/set/operate method 1) Select the item, and then press OK key.
2) Check that OK is displayed.
3) Turn OFF/ON the main power switch.
Caution
- Unless this item is executed at the time of replacement/discard of
the device, the key pair, certificate and CRL which are additionally
registered by the user remain in the HDD, which cause security
concerns.
- Do not execute this item carelessly because the key pair, certificate
and CRL which are additionally registered are deleted when it is
executed. If they are deleted mistakenly, they need to be again
registered by the user. If there is no additional registration, the
machine condition becomes equivalent to the one at the time of factory
shipment.
- If NG is displayed in 2), the key pair, certificate and CRL may not
be deleted. In this case, surely execute the deletion by initializing the
HDD, etc.
Display/adj/set range
At normal state: OK, At failure occurrence: NG
Supplement/memo
By turning OFF/ON the main power switch after execution of this item,
the key pair, certificate and CRL registered by the user are initialized,
and then those registered at the time of factory shipment are extracted
from the archive data.