Service Mode > COPIER > OPTION > LCNS-TR
Service Mode > COPIER > OPTION > LCNS-TR
COPIER>OPTION>ACC
MIC-TUN
Manual adj of voice recognize microphone
Lv.1 Details
To manually adjust the voice receiving level (sensitivity) of the
connected voice recognition microphone.
Microphone sensitivity is automatically tuned in Settings/Registration
menu; however, adjust it manually as needed.
Use case
When the sensitivity of microphone is not improved by automatic
tuning
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range 0 to 255
Default value
128
Related user mode
Preferences> Accessibility> Voice Navigation Settings> Tune
Microphone
SRL-SPSW
Setting of Serial I/F Kit support
Lv.1 Details
To set the support level of the Serial Interface Kit.
To keep processing performance of the printer engine, set 1.
To correctly stop the output by the upper limit number of sheets, set 2.
Use case
At installation of Serial Interface Kit
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Caution
When 1 is set, output cannot be correctly stopped by the upper limit
number of sheets.
When 2 is set, processing performance of the printer engine is
decreased depending on pickup location.
Display/adj/set range 0 to 2
0: No support, 1: Priority on speed, 2: Priority on upper limit number of
sheets
Default value
0
PDL-THR
ON/OFF PDL print: external charge mode
Lv.2 Details
To set whether to execute normal PDL print when COIN is set to
external charge mode 6/7.
Use case
When executing normal PDL print in external charge mode
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range 0 to 1
0: OFF, 1: ON
Default value
0
Related service mode COPIER> OPTION> ACC> COIN
CR-TYPE
[Not used]
COPIER>OPTION>ACC
MEAP-SRL
Set to allow serial comctn from MEAP app
Lv.1 Details
To set whether to allow serial communication of MEAP application.
When 1 is set, serial communication of the machine is stopped and
only the serial communication with MEAP application is available.
Use case
When performing serial communication from MEAP application
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range 0 to 1
0: Prohibited, 1: Allowed
Default value
0
■
INT-FACE
COPIER>OPTION>INT-FACE
NWCT-TM
Setting of network connection timeout
Lv.2
Details
To set the time to keep network connection between the machine
and the PC application (keep-alive setting).
As the value is changed by 1, the time is changed by 1 minute.
Use case
When using PC application
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
1 to 5
Unit
1 min
Default value
5
Supplement/memo
Expected PC application: Network print application, E-mail function,
cascade copy, MEAP network application, etc.
T-8-59