8
8
8-60
8-60
Service Mode > COPIER > ADJUST > DENS
Service Mode > COPIER > ADJUST > DENS
■
DENS
COPIER>ADJUST>DENS
SGNL-Y
ATR patch Y-clr toner dens tgt VL entry
Lv.1 Details
To enter the Y-color toner density target value of ATR patch to be
formed on the ITB.
The Y-color toner density is detected by the Registration Patch Sensor
Unit (Rear).
The value is determined whenever the Developing Unit (Y) is initialized.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after the
processing is done
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When INISET-Y is executed, the value is rewritten.
Display/adj/set range 0 to 1023
Default value
350 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y
SGNL-M
ATR patch M-clr toner dens tgt VL entry
Lv.1 Details
To enter the M-color toner density target value of ATR patch to be
formed on the ITB.
The M-color toner density is detected by the Registration Patch Sensor
Unit (Rear).
The value is determined whenever the Developing Unit (M) is initialized.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after the
processing is done
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When INISET-M is executed, the value is rewritten.
Display/adj/set range 0 to 1023
Default value
350 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-M
SGNL-C
ATR patch C-clr toner dens tgt VL entry
Lv.1 Details
To enter the C-color toner density target value of ATR patch to be
formed on the ITB.
The C-color toner density is detected by the Registration Patch Sensor
Unit (Front).
The value is determined whenever the Developing Unit (C) is initialized.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after the
processing is done
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When INISET-C is executed, the value is rewritten.
Display/adj/set range 0 to 1023
Default value
350 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-C
COPIER>ADJUST>DENS
REF-Y
Y-color toner density target VL entry
Lv.1 Details
To enter the target value of the ATR Sensor (Y) of ATR control after
replacement of the DC Controller PCB/clearing of RAM data.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after clearing
of the data
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range 0 to 255
Default value
120 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-Y/4
REF-M
M-color toner density target VL entry
Lv.1 Details
To enter the target value of the ATR Sensor (M) of ATR control after
replacement of the DC Controller PCB/clearing of RAM data.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after clearing
of the data
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range 0 to 255
Default value
120 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-M/4
REF-C
C-color toner density target VL entry
Lv.1 Details
To enter the target value of the ATR Sensor (C) of ATR control after
replacement of the DC Controller PCB/clearing of RAM data.
Use case
When checking the value before replacement of the DC Controller
PCB/clearing of RAM data and then re-entering the value after clearing
of the data
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range 0 to 255
Default value
120 (It may vary by initialization of the Developing Unit when clearing
RAM data.)
Related service mode COPIER> FUNCTION> INSTALL> INISET-C/4