7
7
7-37
7-37
Error•Jam•Alarm■>■Error■Code■>■Error■Code■Details
Error•Jam•Alarm■>■Error■Code■>■Error■Code■Details
Error■
code
Detail■
Code Location
Item
Description
E196 000F 05
Title
Communication■error
Detection■
description
The■number■of■read/write■job■data■to■the■DCON■EEPROM■
exceeded■100.
Remedy
[Remedy]■Turn■OFF■and■then■ON■the■main■power.
[Reference]■Data■(device■information)■is■reset■by■turning■OFF■and■
then■ON■the■main■power.
E196 0100 05
Title
Communication■error
Detection■
description
The■NACK■(a■negative■reply■sent■by■the■reception■side■to■the■
sending■side)■was■received■3■times■in■communication■from■the■
DC■Controller■PCB■(CPU)■to■the■SCNR■EEPROM.
Remedy
[Related■parts]
•■ Harness■between■the■DC■Controller■PCB■(UN04/J111)■and■
the■Y/M■Laser■Driver■PCB■(UN08/J202)■(Unit■of■replacement:■
CABLE,■CASSETTE■SIZE)
•■ Harness■between■the■DC■Controller■PCB■(UN04/J114)■and■the■
Secondary■Transfer■High■Voltage■PCB■(UN03/J501)■(Unit■of■
replacement:■CABLE,■2ND■TRNSFR.■H.V.■PCB)
•■ Y/M■Laser■Driver■PCB■(UN08)■(Unit■of■replacement:■LASER■
SCANNER■ASSEMBLY)
•■ Secondary■Transfer■High■Voltage■PCB■(UN03)■(Unit■of■
replacement:■2ND■TRNSFR.■H.V.■PCB■ASS'Y)
•■ DC■Controller■PCB■(UN04)■(Unit■of■replacement:■DC■
CONTROLLER■PCB■ASSEMBLY)
[Remedy]■Check/replace■the■related■harness/cable,■connector■
and■parts.
[Reference]■Before■replacing■the■DC■Controller■PCB,■back■up■the■
service■mode■data■(approx.■2■min)■and■restore■the■backup■data■
after■the■replacement■so■the■data■may■be■able■to■be■protected.
•■ Backup:■COPIER■(LEVEL2)>■FUNCTION>■SYSTEM>■
DSRAMBUP
•■ Restoration:■COPIER■(LEVEL2)>■FUNCTION>■SYSTEM>■
DSRAMRES
Error■
code
Detail■
Code Location
Item
Description
E196 0101 05
Title
Communication■error
Detection■
description
Although■access■to■the■SCNR■EEPROM■from■the■DC■Controller■
PCB■(CPU)■was■performed■3■times,■no■response■was■received■
and■timeout■occurred.
Remedy
[Related■parts]
•■ Harness■between■the■DC■Controller■PCB■(UN04/J111)■and■
the■Y/M■Laser■Driver■PCB■(UN08/J202)■(Unit■of■replacement:■
CABLE,■CASSETTE■SIZE)
•■ Harness■between■the■DC■Controller■PCB■(UN04/J114)■and■the■
Secondary■Transfer■High■Voltage■PCB■(UN03/J501)■(Unit■of■
replacement:■CABLE,■2ND■TRNSFR.■H.V.■PCB)
•■ Y/M■Laser■Driver■PCB■(UN08)■(Unit■of■replacement:■LASER■
SCANNER■ASSEMBLY)
•■ Secondary■Transfer■High■Voltage■PCB■(UN03)■(Unit■of■
replacement:■2ND■TRNSFR.■H.V.■PCB■ASS'Y)
•■ DC■Controller■PCB■(UN04)■(Unit■of■replacement:■DC■
CONTROLLER■PCB■ASSEMBLY)
[Remedy]■Check/replace■the■related■harness/cable,■connector■
and■parts.
[Reference]■Before■replacing■the■DC■Controller■PCB,■back■up■the■
service■mode■data■(approx.■2■min)■and■restore■the■backup■data■
after■the■replacement■so■the■data■may■be■able■to■be■protected.
•■ Backup:■COPIER■(LEVEL2)>■FUNCTION>■SYSTEM>■
DSRAMBUP
•■ Restoration:■COPIER■(LEVEL2)>■FUNCTION>■SYSTEM>■
DSRAMRES
E196 010F 05
Title
Communication■error
Detection■
description
The■number■of■read/write■job■data■to■the■SCNR■EEPROM■
exceeded■100.
Remedy
[Remedy]■Turn■OFF■and■then■ON■the■main■power.
[Reference]■Data■(device■information)■is■reset■by■turning■OFF■and■
then■ON■the■main■power.