8
8
8-167
8-167
Service Mode > COPIER > OPTION > FEED-SW
Service Mode > COPIER > OPTION > FEED-SW
COPIER > OPTION > ENV-SET
CLD-REV
Set reverse rotation: Photo-s Drum stop
Lv.2 Details
To set whether to rotate the CL Drum Motor reversely when the
Photosensitive Drum (Y/M/C) is stopped.
Performing reverse rotation enables to prevent white lines in horizontal
scanning direction due to the backlash of stop, but noise may occur in
a low temperature environment.
When 0 is set, reverse rotation is turned OFF if room temperature is
lower than 10 deg C, and ON if the temperature is 10 deg C or higher.
Use case
- When noise occurs at reverse rotation of the drum
- When uneven density/blur at intervals of drum circumference occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
Without performing reverse rotation, uneven density/blur at intervals of
drum circumference may occur.
Display/adj/set range 0 to 2
0: OFF when room temperature is lower than 10 deg C, and ON when
the temperature is 10 deg C or higher, 1: ON, 2: OFF
Default value
0
T-8-53
■
FEED-SW
COPIER > OPTION > FEED-SW
EVLP-SPD
Setting of envelope feeding speed
Lv.1 Details
To set the feeding speed of envelope.
By feeding an envelope at 1/2 speed (default) in the case of a high
humidity environment, the glue flap may adhere at the time of fixing.
As a result of that, the envelope may not be opened.
When 1/1 speed is set, adhesion can be prevented, but fixing
performance is decreased in a low humidity environment.
Use case
When a glue flap of envelope adheres
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When 1 is set in a low humidity environment, fixing performance is
decreased.
Display/adj/set range
0 to 1
0: 1/2 speed, 1: 1/1 speed
Default value
0
Related service mode
COPIER> OPTION> FEED-SW> EVLP-FS
PINT-REG
Set img pstn crrct exe frqcy: ppr intvl
Lv.2 Details
To set the frequency to execute image position correction control at
paper interval.
When 1 is set, frequency is increased. Compared with the default
setting, the interval becomes shorter. In addition, the machine
becomes sensitive to change in temperature and the control is
executed even with B&W image. Color displacement is less likely to
occur, but productivity is decreased.
Use case
When color displacement occurs frequently
Adj/set/operate method Enter the setting value, and then press OK key.
Caution
When 1 is set, productivity is decreased.
Display/adj/set range
0 to 1
0: Default, 1: High frequency
Unit
-
Default value
0
EVLP-FS
Setting of fixing speed: envelope
Lv.2 Details
To set fixing speed when feeding envelope.
As the value is changed by 1, the fixing speed is changed by 0.1%.
Decrease the value when fine line displacement occurs on trailing
edge of envelope, and increase the value when wrinkles occur.
Use case
When fine line displacement or wrinkles occur on trailing edge while
feeding envelope
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
Be sure to change the value a little at a time. Otherwise, fine line
displacement/wrinkles occur when setting an extreme value.
Display/adj/set range
-20 to 20
Unit
0.1 %
Default value
0
Related service mode
COPIER> OPTION> FEED-SW> EVLP-SPD
T-8-54