AXIS 7100
User’s Manual
Meta Information
129
Example: RightFax Integration (SMTP)
RightFax Server
In this example the user is prompted to enter the fax number
when the FAX destination is selected from the list. The XML DD
file in this example generates the required message.
XML DD file
The XML code is now complete. Save the file on an FTP server
and proceed to “
Retrieving the XML DD file
” on page 133 for
information on how to configure the AXIS 7100 to retrieve the
XML DD file.
Entering the
Required Meta
Information
When the user wants to scan and send a document to a fax, the
fax destination is selected from the list:
<?xml version="1.0"?>
<!DOCTYPE MetaDataFile SYSTEM "metadata.dtd">
<MetaDataFile>
<Ask><When><Destination Description=“FAX”/></When>
<MetaData Required = "yes"
Id = "FAX_NUM_IETF"
Prompt = "Fax Number:"
ErrorMessage = "Invalid number"
Pattern = "[0-9]+"
/>
<Output
Description=”fax=$FAX_NUM_IETF$fax.company.com”>
</Output>
</Ask>
</MetaDataFile>
Send to:
FAX