Chapter 9: Using Tools
287
10. The Select Firmware Files for Migration window will open. Select the file image in the
Available Firmware Files list, then click
Add
. The selected file will be moved to the Firmware
File To Update list. Click
Next
.
If needed, the firmware file may be added to the DSView 3 software system from the
Appliance Firmware Files window (accessed by selecting the
System
tab,
Appliance Files
in
the top navigation bar, and
Firmware Files
in the side navigation bar).
11. The Enter in Login Credentials window will open.
a.
In the Username field, enter a 3-16 character username. This username must be the same
for all CCM appliances selected for migration; otherwise, the appliance without this
username will fail to migrate.
b.
The Password field is optional. If specified, the password must be 3-16 characters.
c.
Click
Next
.
12. The Completed Successful window will open. Click
Finish
. The Tasks window will open. You
may display the current progress of the Migrate Units task as it is running by clicking on the
name of the task.
13. Repeat the preceding steps for each type of CCM appliance that you wish to migrate.
Units successfully migrated into your DSView 3 software system will appear in Units View
windows and the Migration Status field for these units will indicate Migration Complete.
Task: Sending an IPMI chassis control command to target devices
This command powers up, powers down, cycles the power (power down and then power up),
performs a gentle shutdown or resets one or more IPMI target devices.
You must have Control Target Device Power rights to send an IPMI chassis control command. See
About Access Rights
on page 120.
Once this task is added, you may run it on demand at any time; see
Running tasks manually
on
page 289. For another way to control power of an IPMI target device, see
Controlling IPMI target
device power
on page 252.
To add the task:
1.
Click the
System
tab.
2.
Click
Tasks
in the top navigation bar. The Tasks window will open.
3.
Click
Add
. The Add Task Wizard will appear. Click
Next
.
4.
The Select Task to Add window will open.
a.
Select
Send IPMI chassis control command to target devices
from the drop-down menu.
b.
Type a 1-64 character name for the task.
c.
Click
Next
.
5.
The Select When to Run the Task window will open. Select a time to run the task (see
Specifying when to run tasks
on page 278). Click
Next
.
Summary of Contents for DSView 3
Page 1: ...Installer User Guide DSView 3...
Page 2: ......
Page 4: ......
Page 16: ...xiv DSView 3 Software Installer User Guide...
Page 54: ...36 DSView 3 Software Installer User Guide...
Page 66: ...48 DSView 3 Software Installer User Guide...
Page 196: ...178 DSView 3 Software Installer User Guide...
Page 266: ...248 DSView 3 Software Installer User Guide...
Page 282: ...264 DSView 3 Software Installer User Guide...
Page 320: ...302 DSView 3 Software Installer User Guide...
Page 326: ...308 DSView 3 Software Installer User Guide...
Page 372: ...354 DSView 3 Software Installer User Guide...
Page 383: ......