98
DSView 3 Software Installer/User Guide
For appliances supported by plug-ins, the content of this window may differ; see the
appropriate documentation.
a.
Enable the
Enable secure mode
checkbox if you want the managed appliance to only be
accessible by this DSView 3 software system. In non-secure mode, the managed appliance
may be added to multiple DSView 3 software systems.
This checkbox will not appear when adding a DSI5100 appliance, which may only be
added in Secure mode.
b.
Enable the
Allow target devices with the same name to be merged into a single target
device
checkbox if you wish to merge a target device that has multiple connections into a
single target device.
c.
Under
Allow target devices that contain default names to be added for these type of
connections
, you may enable the checkboxes for one or more connection types. Any target
devices that contain default names in the managed appliance and support the enabled
connection type in the managed appliance will be added to the DSView 3
software database.
This option has no effect when adding a DSI5100 appliance, since default target device
names are not supported. A target device is named when it is added as a BMC port using
the Add IPMI BMC Wizard.
d.
Click
Next
.
8.
If one or more cascade switches are connected to the managed appliance, the Configure
Cascade Switches window will open.
a.
Select the type of cascade switch for each row from the menu in the Cascade Switch
Type column.
b.
Optionally, type a name for each row in the Name column.
c.
If two or more rows of a multiuser cascade switch are discovered, you can merge the rows
by selecting the checkboxes of those rows and clicking
Merge
. To undo the merge, click
the row of the merged switch and click
Split
. For information about other methods for
merging cascade switches, see
Topology Synchronization
on page 109.
d.
Click
Next
.
9.
The Completed Successful window will open.
When you add a CCM appliance that is using firmware compatible with AVWorks software,
you will be alerted that it must be migrated, along with a link named Add Migration Task,
which will take you to the Add Task Wizard.
10. Click
Finish.
Adding a single embedded appliance
This procedure is valid only for IBM ASM RSA II, DRAC 4, HP iLO and NEC IPF
embedded appliances.
Summary of Contents for DSView 3
Page 1: ...Installer User Guide DSView 3...
Page 2: ......
Page 4: ......
Page 16: ...xiv DSView 3 Software Installer User Guide...
Page 54: ...36 DSView 3 Software Installer User Guide...
Page 66: ...48 DSView 3 Software Installer User Guide...
Page 196: ...178 DSView 3 Software Installer User Guide...
Page 266: ...248 DSView 3 Software Installer User Guide...
Page 282: ...264 DSView 3 Software Installer User Guide...
Page 320: ...302 DSView 3 Software Installer User Guide...
Page 326: ...308 DSView 3 Software Installer User Guide...
Page 372: ...354 DSView 3 Software Installer User Guide...
Page 383: ......