COMfortel 1100 - Firmware Version 4.4 - COMfortel Set V2.7 - Version of the Manual 04 11/10
149
Configuring and Operating Functions
Door Functions
Configuring and Operating Function Key for Door Functions
Door Functions
A door terminal system connected with the interface FTZ 123 D12-0 (PBX requires extension
module) enables the following functions. Calls to the door can be made from any telephone
(intercom). During a call to the door, the door can be opened (open door) and a stairwell light
controlled by switching a relay (switch on light).
These functions can be executed on the system telephone without initiating a door call.
Configuring and Operating Function Key for Door Functions
Important: Not available for operation on the PBXs COMpact 2204 USB and
COMpact 3000.
Press the key to initiate a call connection with the door (after picking up the receiver) or to switch
on the door opener and/or light.
In addition, when functions are defined on the first key level, the status of the function is
indicated by the corresponding LED.
The configuration can be carried out as follows:
• Via COMfortel Set
Configuring Function Key for Defined Door Terminal Functions via COMfortel Set
Requirements:
– An open configuration and the required PIN, if necessary
– The authority level assigned in the PBX for the door terminal
– The relays configured in the PBX for the intercom, opening the door and the stairwell light
LED signalling next to the key:
Green
The door opener function is enabled.
Red
A call connection has been established with the door.
Yellow
The light is switched on.
Off
None of the functions configured on the key are enabled.
Summary of Contents for COMfortel 1100
Page 273: ...04 11 10...