1 Introduction
10
ARGUS 152
Note:
Detailed explanations regarding the Copper Box may be found in the separate
documentation for the respective device.
You should receive these together with your equipment. You can also download
the latest manuals at http://www.argus.info/en/service/downloads, or simply
contact our Service Department:
intec Gesellschaft für Informationstechnik mbH
Rahmedestr. 90
D-58507 Lüdenscheid
Tel.: +49 (0) 2351 / 9070-0
Fax: +49 (0) 2351 / 9070-70
www.argus.info/en
POTS functions
-
Fully functional integrated analogue handset (POTS)
-
With DTMF and CLIP display, pulse dialling
-
High-ohm 2-wire monitor with voltage measurement
-
Assessment of analogue speech quality directly at POTS access
- PESQ (ITU-T P.862) + MOS
LQO
in conjunction with PESQ server SW
Copper test (Cu test) functions
-
Copper Box:
expansion of the ARGUS copper test function, see ARGUS Copper Box
manual
-
R-measurement:
ARGUS continually measures resistance and displays the values in
real time (loop resistance)
-
RC measurement:
Test of loop resistance or capacitance of open line (including
calculation of line length)
-
Line Scope:
High-performance realtime Line Scope with display in time and
frequency range (FFT) up to 30 MHz
-
TDR:
Time domain reflectometer to measure line lengths and locate faults
-
Line qualification:
Checking of the local loop for its suitability for DSL, including a
DSL data rate estimation
-
Line symmetry:
The line symmetry measures the frequency-dependent symmetry
of a pair of cores
Local loop acceptance log
When connected to a PC via a USB port, ARGUS can be used to generate and print out a
detailed measurement log on the PC using the software WINplus / WINanalyse.