MAWA-050A
4. Explanation of Screens
4-30
(11) Monitor
Select
Screen
This screen is used to set the data to be obtained at welding and the data to make an upper/lower
limit judgment. This setting can be performed for each condition No.
(a) SCH
The currently selected condition No. is displayed.
(b) Monitor range
Set a range to make an upper/lower limit judgment of monitor value.
One of “WELD1+WELD2”, “WELD1” and “WELD2” can be selected.
The threshold value of upper/lower limit judgment can be set individually for WELD1
and WELD2 on the Upper/lower limit set screen.
WELD1+WELD2 An upper/lower limit judgment is performed in both ranges of
WELD1 and WELD2.
WELD1
An upper/lower limit judgment is performed only for the range
of WELD1 but not performed for the range of WELD2.
WELD2
An upper/lower limit judgment is performed only for the range
of WELD2 but not performed for the range of WELD1.
[Initial value: WELD1+WELD2]
Upper/lower limit
judgment range of WELD1
WELD1 lower limit
WELD1 upper limit
WELD2 lower limit
WELD2 upper limit
Upper/lower limit
judgment range of WELD2