MAWA-050A
4. Explanation of Screens
4-41
(17) Password Setting Screen
In this welding power supply, it can be protected to go to a specific setting screen by entering a
password. The following screen is used to set a password and select the validity/invalidity of the
password.
(a) Password input area (4-digit number max.)
The ten-key pad is displayed by touching this area. Enter a password to be
registered by using a 4-digit number. Enter a numeric value except “0.”
[Initial value: 0 (password invalidated)]
(b) Regist
The input password can be registered by pressing this switch after entering the
password. If the operator goes to a screen without pressing this switch, the entered
password will be invalided.
After completion of registration, “Password was registered.” Is displayed on the
screen. The password is required to go to a screen with a mark of
.
When the password input is “0”, “Password was canceled.” is displayed.
If the password input is omitted to go to another screen after registration of the
password, it is possible to go to every screen without the password hereafter until the
power supply is turned on again. To validate the password again, press “Regist” on
this screen.