Command 04 (envelope data) Data for each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
Reference waveform selection
n,
1: Set value
2: Measured value
2
Envelope WELD1 current value upper limit
nn.nn,
00.00 ~ 60.00 (A)
3
Envelope WELD1 current value lower limit
nn.nn,
4
Envelope WELD1 voltage value upper limit
nn.nn,
00.00 ~ 50.00 (V)
5
Envelope WELD1 voltage value lower limit
nn.nn,
6
Envelope WELD2 current value upper limit
nn.nn,
00.00 ~ 60.00 (A)
7
Envelope WELD2 current value lower limit
nn.nn,
8
Envelope WELD2 voltage value upper limit
nn.nn,
00.00 ~ 50.00 (V)
9
Envelope WELD2 voltage value lower limit
nn.nn
Remarks
Data of “Env Wave regist” (envelope waveform registration) cannot be written.
Command 05 (production count data) Data for each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
TORCH 1 preset count set value
nnnnnn,
000000 ~ 999999
2
TORCH 1 workpiece count set value
nnnnn,
00000 ~ 60000
3
TORCH 1 WELD count set value
nnn,
000 ~ 255
4
TORCH 2 preset count set value
nnnnnn,
000000 ~ 999999
5
TORCH 2 workpiece count set value
nnnnn,
00000 ~ 60000
6
TORCH 2 WELD count set value
nnn
000 ~ 255