MAWA-050A
4. Explanation of Screens
4-19
Switch selection screen (2/2)
(a) Torch drive type
Regarding the motive power to operate the torch, either “MOTOR” or “CYLINDER”
can be selected. Perform this setting according to your torch.
[Initial value: MOTOR]
(b) GOOD/NG signal output time
After the end of all the welding sequence, the GOOD/NG signal output time can be
set. The setting range is 1 ~ 200 [ms]. The upper/lower limit judgment of the
monitor value is also output with this setting.
[Initial value: 200 ms]
(c) END signal output time
After the end of all the welding sequence, the END signal output time can be set.
The setting range is 1 ~ 200 [ms]. [Initial value: 200 ms]
(d) START signal input delay time
Sets the time to determine the condition after the START signal is input.
If the START signal is input over the set time, the welding sequence is started.
The condition No. for welding is determined by the SCH (1 ~ 64) signal at the time
when the set time is elapsed. The setting range is 1 ~ 200 [ms]. [Initial value: 20
ms]
Also, if the START signal is turned off in the time set in this item after a START signal
input, the welding sequence is not started.
START signal input decision delay time
START signal input decision delay time