MAWA-050A
3. Operating Unit
3-2
START button (with a green LED incorporated)
When “CYLINDER” is set for the Torch drive type, this button LED lights (in green) when welding
is ready. When the START key of the panel is made effective on the Switch select screen,
welding is started by pressing this button while it lights. (Refer to “4. (6) Switch Select
Screen.”)
When“MOTOR” is set for the Torch drive type, this button LED does not light even when welding
is ready since the welding starts by the initial current start signal (H-ST1) of the option
input/output connector. (Refer to “2. (3)-1-3 Option input/output connector.”)
RESET button (with an orange LED incorporated)
This button LED lights (in orange) when an error occurs. The error will be cleared by pressing
this button after removing the cause of the error, and then the button LED goes out.
Emergency stop button
The welding power supply can be put to an emergency stop by pressing this button.
There are two ways to release the emergency stop, pulling operation and rotating operation.
Pulling operation
Rotating operation