MAWA-050A
7. External Communication Function
7-5
(2) Error data
Data strings
!01 001 S07:E03,04, 12, 15, 17, 19, 22, 24 [CR][LF]
A B C D E F G H I J K
A
Device No.
Fixed 2 digits of 01 ~ 31
B
Condition No.
Fixed 3 digits of 001 ~ 127
C
Command No.
Fixed 3 digits of S07
D (*1)
Error code 1
Fixed 3 digits of E01 ~ E28
E (*1)
Error code 2
Fixed 2 digits of 01 ~ 28
F (*1)
Error code 3
Fixed 2 digits of 01 ~ 28
G (*1)
Error code 4
Fixed 2 digits of 01 ~ 28
H (*1)
Error code 5
Fixed 2 digits of 01 ~ 28
I (*1)
Error code 6
Fixed 2 digits of 01 ~ 28
J (*1)
Error code 7
Fixed 2 digits of 01 ~ 28
K (*1)
Error code 8
Fixed 2 digits of 01 ~ 28
*1: Up to 8 error codes are used. When one error exists, E ~ K are omitted.
For error codes, refer to “8. (2) Error Messages.” E is attached to only Error code 1.
*2: When an error is detected, the error code will be transmitted.