MAWA-050A
4. Explanation of Screens
4-45
Screen Parameter
Initial
value
Monitor select
screen (all of
condition Nos.
1 ~ 127)
Monitor value measuring range
WELD1+WELD2
Slope time
Exclude
Upper/lower limit judgment
output
Current value
OFF
Voltage value
OFF
Weld time
OFF
Envelope OFF
Upper/lower
limit set screen
(all of condition
Nos. 1 ~ 127)
Current value
Upper limit
value
WELD1 60.00
[A]
WELD2 60.00
[A]
Lower limit
value
WELD1 0.00
[A]
WELD2 0.00
[A]
Voltage value
Upper limit
value
WELD1 50.00
[V]
WELD2 50.00
[V]
Lower limit
value
WELD1 0.00
[V]
WELD2 0.00
[V]
Time
Upper limit
value
WELD1 5000
[ms]
WELD2 5000
[ms]
Lower limit
value
WELD1 0
[ms]
WELD2 0
[ms]
Password
setting screen
Password
0
(No password setting)
Count setting
screen
TORCH1
Preset count
0
Work count preset
0
WELD count preset
0
Total count
0
Work count
0
Weld count
0
TORCH2
Preset count
0
Work count preset
0
WELD count preset
0
Total count
0
Work count
0
Weld count
0