MAWA-050A
5. Welding
5-5
(4)
Welding Condition Setting
(4) -1. Registering the welding conditions
Registering the welding conditions will be described below.
In
MAWA-050A
, up to 127 types of the welding condition can be registered. Register the welding
conditions on the Welding conditions setting screen.
Remarks
The welding condition setting screen consists of 2 types.
- FULL SETTING screen: Every setting item can be set.
- SIMPLE SETTING screen: A small number of setting items can be set easily.
Displaying the Welding condition setting screen
1. Press MENU in the upper right part of the
screen.
The Menu screen is displayed.
2. On the Menu screen, press “Welding condition set”
on the Menu screen.
The FULL SETTING screen of the Welding
condition setting screen is displayed.
For the details of the FULL SETTING screen, refer
to “4. (9)
FULL SETTING screen.”
Depress SIMPLE for about a sencond on the
FULL SETTING screen, and the SIMPLE
SETTING screen will be displayed.
For the details of the SIMPLE SETTING screen,
refer to “4. (9)
SIMPLE SETTING screen.”