MAWA-050A
7. External Communication Function
7-8
(5)
Data Code Table
Command 01 (condition data) Data for each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
Torch No.
nn,
01: TORCH 1 02: TORCH 2
2
Condition setting mode
nn,
01: FULL setting mode
02: SIMPLE setting mode
3
Initial current value (*1)
nn.nn,
05.00 ~ 09.99 (A) (in units of 0.01 A)
10.00 ~ 50.00 (A) (in units of 0.10 A)
*1: Range for initial current value and
WELD1 up-slope initial current
01.00 ~ 09.99 (A) (in units of 0.01 A)
4
WELD1 up-slope initial current (*1)
5
WELD1 up-slope final current
6
WELD1 main welding current
7
WELD1 down-slope initial current
8
WELD1 down-slope final current
9
Cooling in-process current value
10
WELD2 up-slope initial current
11
WELD2 up-slope final current
12
WELD2 main welding current
13
WELD2 down-slope initial current
14
WELD2 down-slope final current
15
Pre-flow time
nnnn,
0000 ~ 9999 (ms)
16
Initial current time
nnn,
000 ~ 999 (ms)
17
WELD1 up-slope time
nnn.n,
000.0 ~ 099.9 (ms) (in units of 0.1 ms)
100.0 ~ 999.0 (ms) (in unit of 1 ms)
18
WELD1 main welding time
19
WELD1 down-slope time
20
Cooling time
nnnn,
0000 ~ 1000 (ms)
21
WELD2 up-slope time
nnn.n,
000.0 ~ 099.9 (ms) (in units of 0.1 ms)
100.0 ~ 999.0 (ms) (in unit of 1 ms)
22
WELD2 main welding time
23
WELD2 down-slope time
24
After-flow time
nnnn,
0000 ~ 9999 (ms)
25
WELD1 pulse modulation ON/OFF
n,
0: OFF 1: ON
26
WELD1 modulation frequency
nnnn,
0000 ~ 3000 (Hz)
27
WELD1 modulation duty ratio
nnn,
10 ~ 90 (%)
28
WELD1 slope section modulation
ON/OFF
n, 0:
OFF
1:
ON
29
WELD1 base current value
nn.nn,
01.00 ~ 09.99 (A) (in units of 0.01 A)
10.00 ~ 50.00 (A) (in units of 0.10 A)
30
WELD2 pulse modulation ON/OFF
n,
0: OFF 1: ON