MAWA-050A
7. External Communication Function
7-9
Item Contents
Character
string
Range
31
WELD2 modulation frequency
nnnn,
0000 ~ 3000 (Hz)
32
WELD2 modulation duty ratio
nnn,
10 ~ 90 (%)
33
WELD2 slope section modulation
ON/OFF
n, 0:
OFF
1:
ON
34
WELD2 base current value
nn.nn
05.00 ~ 09.99 (A) (in units of 0.01 A)
10.00 ~ 50.00 (A) (in units of 0.10 A)
Command 02 (upper/lower limit setting) Data or each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
WELD1 current value upper limit
nn.nn,
00.00 ~ 60.00 (A)
2
WELD1 current value lower limit
nn.nn,
3
WELD1 voltage value upper limit
nn.nn,
00.00 ~ 50.00 (V)
4
WELD1 voltage value lower limit
nn.nn,
5
WELD1 weld time upper limit
nnnn,
0000 ~ 5000 (ms)
6
WELD1 weld time lower limit
nnnn,
7
WELD2 current value upper limit
nn.nn,
00.00 ~ 60.00 (A)
8
WELD2 current value lower limit
nn.nn,
9
WELD2 voltage value upper limit
nn.nn,
00.00 ~ 50.00 (V)
10
WELD2 voltage value lower limit
nn.nn,
11
WELD2 weld time upper limit
nnnn,
0000 ~ 5000 (ms)
12
WELD2 weld time lower limit
nnnn
Command 3 (monitor item setting) Data for each condition No. (Condition No.: 001 ~ 127)
Item Contents
Character
string
Range
1
Monitor value measuring range
n,
0: WELD1 + WELD2
1: WELD1 only
2: WELD2 only
2
Whether the slope time is included in the monitor n,
0: Exclude 1: Include
3
Current value upper/lower limit judgment output
n,
0: OFF 1: ON
4
Voltage value upper/lower limit judgment output
n,
0: OFF 1: ON
5
Weld time upper/lower limit judgment output
n,
0: OFF 1: ON
6
Envelope upper/lower limit judgment output
n
0: OFF 1: ON