![Amada PULSETIG MAWA-050A Operation Manual Download Page 170](http://html1.mh-extra.com/html/amada/pulsetig-mawa-050a/pulsetig-mawa-050a_operation-manual_2915804170.webp)
MAWA-050A
8. Troubleshooting
8-1
8. Troubleshooting
(1) Error
Screen
When an error occurs in the welding power supply, the Error screen will be displayed on the touch
panel display. The error code, error message, condition No. at occurrence of the error, and error
occurrence time after turning on the welding power supply are displayed.
After removing the cause of the error, press the “RESET” button on the front panel or enter the
“RESET” signal. Then, a recovery can be made from the error status. If the cause of the error is not
removed, the Error screen will be displayed again.
If an error display is disabled because communication with the touch panel display cannot be
performed, the buzzer of the welding power supply sounds continuously. Turn on the power supply
again.
(a) SCH
The condition No. selected at occurrence of an error is displayed.
(b) MESSAGE
The error code of the current error and an error message are displayed in red characters.
(c) Time
(min)
The minutes elapsed after the power supply of the welding power supply is turned on at
occurrence of an error are displayed.
E03 Overheat error
E01 Emergency STOP