MAWA-050A
4. Explanation of Screens
4-22
(8)
Ext I/O Setting Screen
Set inputs IN1/IN2 and outputs OUT1 ~ OUT7 of external input/output signals.
Select them by “+” and “-.” The display is changed in the following order.
User input terminals
01.GAS FLOW
02.H-ORG
03.H-HEAD UP
User output terminals
01.GOOD 02.NG
03.END
04.ERROR 05.READY 06.LOST
07.WEL1 LOWER CURRENT
08.WEL1 UPPER CURRENT
09.WEL1 LOWER VOLTAGE
10.WEL1 UPPER VOLTAGE
11.WEL1 LOWER TIME
12.WEL1 UPPER TIME
13.WEL1 LOWER ENVELOPE CUR 14.WEL1 UPPER ENVELOPE CUR 15.WEL1 LOWER ENVELOPE VLT
16.WEL1 UPPER ENVELOPE VLT
17.WEL2 LOWER CURRENT
18.WEL2 UPPER CURRENT
19.WEL2 LOWER VOLTAGE
20.WEL2 UPPER VOLTAGE
21.WEL2 LOWER TIME
22.WEL2 UPPER TIME
23.WEL2 LOWER ENVELOPE CUR 24.WEL2 UPPER ENVELOPE CUR
25.WEL2 LOWER ENVELOPE VLT
26.WEL2 UPPER ENVELOPE VLT
27.SYNC.OUT
28.WIRE START
29.H-READY
30.H-ST1
31.H-ST2 32.H-ERROR
33.H-HEAD
UP
34.H-MODE 35.MID
POINT
For the contents of each input/output signal, refer to “2. (3)-3. External input/output signal table.”
(a) User input terminal
A signal to be allocated to user input terminal 1/2 can be selected. When the setting
is “User input terminal”, no input signal exists.
(b) User output terminal
A signal to be output from user output terminals 1 ~ 7 can be selected. When the
setting is “User output terminal”, no output signal exists.
(c) Screen feed switch
The Basic setting screen is displayed.
(d) Screen return switch
The Switch select screen (2/2) is displayed.
(a)
(b)
(d)