MAWA-050A
7. External Communication Function
7-4
(4) Protocol
One-way communication mode
(1) Monitor data (Monitor data is transmitted at each end of communication.)
Data strings
!01 001 S10: 01, 01, 015.0, 01.00, 1111.0, 020.0, 02.00, 2222.2, 100000, 111111,
A B C D E F G H I J K L M
22222, 222 [CR][LF]
N O
Item Contents Character
string
Range
A
Device No.
nn
01 ~ 31
B
Condition No.
nnn
001 ~ 127
C
Command No.
nnn:
Fixed to S10
D
Torch No.
nn,
Fixed to 01
E
Welding result
nn,
01: GOOD 02: NG 03: LOST
F
WELD1 current
nnnn.n,
000.0 ~ 999.9 (A)
G
WELD1 voltage
nn.nn,
00.00 ~ 99.99 (V)
H
WELD1 time
nnnn.n,
0000.0 ~ 9999.0 (ms)
I
WELD2 current
nnn.n,
000.0 ~ 999.9 (A)
J
WELD2 voltage
nn.nn,
00.00 ~ 99.99 (V)
K
WELD2 time
nnnn.n,
0000.0 ~ 9999.0 (ms)
L ALL
COUNT
nnnnnn,
000000 ~ 999999
M
TORCH 1 total count
nnnnnn,
000000 ~ 999999
N
TORCH 1 workpiece count
nnnnn,
00000 ~ 60000
O
TORCH 1 WELD count value
nnn
000 ~ 255