MAWA-050A
7. External Communication Function
7-13
Command 07 (error data) Common data (Condition No.: 000)
Error data check (data reading only: MAWA-050A
→
Host computer)
Item Contents
Character
string
Range
1
Error code 1
nnn,
E01 ~ E28
2
Error code 2
nn,
01 ~ 28
3
Error code 3
nn,
01 ~ 28
4
Error code 4
nn,
01 ~ 28
5
Error code 5
nn,
01 ~ 28
6
Error code 6
nn,
01 ~ 28
7
Error code 7
nn,
01 ~ 28
8
Error code 8
nn
01 ~ 28
Up to 8 error codes can be used. When the number of errors is 1, items 2 ~ 8 will be omitted.
For error codes, refer to “8. (2) Error Messages.”
Error reset (data writing only)
Item Contents
Character
string
Range
1 Error
reset
nnn E00
As reply data, “00” (the status of no error data) is sent back.