MAWA-050A
9. Maintenance
9-3
(2) Periodic Maintenance
(2) -1. Monthly maintenance
(2) -1-1. Cleaning the cooling fan filter
IMPORTANT
When the filter used in the cooling fan of the rear panel is dirty, the air flow will be deteriorated
and the internal temperature of the welding power supply will go up, thereby causing a failure.
How to clean the cooling fan filter will be described below.
Check the cooling fan filter for dirt once a month. If the cooling fan filter is dirty, clean it according to
the following procedure.
1. Remove the hooks (at 4 positions) of the retainer and then remove the retainer and media from
the cooling fan filter of the rear panel.
2. Wash the media with a liquid diluted with a neutral cleaner.
3. After drying the media completely, install the media and retainer.
Replacing the media
If the media of the cooling fan filter is very dirty, replace the media.
Replacement media
Manufacturer OMRON Corporation
Product name Media
Model
R87F-FL90-M90 (1 set: 5-media set)
Retainer
Hook
Media
Cooling fan filter