![Amada PULSETIG MAWA-050A Operation Manual Download Page 105](http://html1.mh-extra.com/html/amada/pulsetig-mawa-050a/pulsetig-mawa-050a_operation-manual_2915804105.webp)
MAWA-050A
4. Explanation of Screens
4-37
(c) Output signal operating switch
Used to turn on/off output signals.
(d) Screen feed switch
The I/O check (OP) screen is displayed.
(e) Screen return switch
The I/O check (OP) screen reappears.
I/O check (OP) screen
This screen is used to operate the input/output signals to be used when the optional servo motor
type welding head or torch selector is used.
(e) Option input terminal state
The input signal status is displayed.
Terminal 1
H-ST1
Terminal 3
H-READY
Terminal 4
GAS
Terminal 5
MID POINT
Terminal 6
H-ST2
Terminal 7
H-ERROR
(f) Option output terminal state
The output signal status is displayed.
Terminal 10 H-END
Terminal 16
H-STOP
Terminal 11 H-ORG
Terminal 18
H-T.SEL
Terminal 12 H-RESET
Terminal 20
H-CY VLV
Terminal 13 M-READY
Terminal 22
H-MODE
Terminal 14 H-HEADUP
Select a signal for selecting ON/OFF
by “
△
” and “
▽
” to select a “ON/OFF”
status.