
MAWA-050A
6. Timing Chart
6-14
(9)
Option Input/Output Signals
The following is a timing chart for option input/output signals (H-ORG and H-HEAD UP).
H-READY入力
H-ORG 出力
H-ORG 入力
H-HEAD UP 入力
通電中
SYNC.OUT出力
*2
*2
*1
H-HEAD UP 出力
*1 After
MAWA-050A
receives an H-ORG input signal, it outputs an H-ORG output signal. (During welding, the H-ORG signal
input is not accepted.) The H-ORG output signal is continuously output until the H-READY signal is received.
*2 After
MAWA-050A
receives an H-HEAD UP input signal, it outputs an H-HEAD UP output signal. (During welding, the
H-HEAD UP signal input is not accepted.) The H-HEAD UP output signal is continuously output for the set time of “H-HEAD
UP signal output time.”
Refer to ”4. (6) Switch Select Screen.”
SYNC OUT output
welding in process
H-ORG input
H-ORG output
H-READY input
H-HEAD UP input
H-HEAD UP output