![Amada PULSETIG MAWA-050A Operation Manual Download Page 167](http://html1.mh-extra.com/html/amada/pulsetig-mawa-050a/pulsetig-mawa-050a_operation-manual_2915804167.webp)
MAWA-050A
7. External Communication Function
7-15
Command 11 (current waveform data check) Common data (Condition No.: 000)
Resistance welding current waveform check (data reading only: MAWA-050A
→
Host computer)
Up to 202 points of current waveform data are transmitted with line feeds. (Line feeds are not
inserted after Interval of acquisition and Number of monitor display waveform data.)
Item Contents Character
string
Range
1
Interval of acquisition
nnnn,
0000 ~ 1350
2
Number of monitor display waveform data nnn,
000 ~ 202
3
Current waveform data point 1
nn.nn
00.00 ~ 50.00 (A)
204
Current waveform data point 202 (Max.)
nn.nn
00.00 ~ 50.00 (A)
Caution
Since the weld time varies according to the head moving time even under the same welding
conditions in the auto mode (including the fine weld mode), Interval of acquisition and Number of
waveform data also vary.
Command 12 (voltage waveform data check) Common data (Condition No.: 000)
Resistance welding voltage waveform check (data reading only: MAWA-050A
→
Host computer)
Up to 202 points of voltage waveform data are transmitted with line feeds. (Line feeds are not
inserted after Interval of acquisition and Number of monitor display waveform data.)
Item Contents Character
string
Range
1
Interval of acquisition
nnnn,
0000 ~ 1350
2
Number of monitor display waveform data nnn,
000 ~ 202
3
Voltage waveform data point 1
nn.nn
00.00 ~ 50.00 (V)
204
Voltage waveform data point 202 (Max.)
nn.nn
00.00 ~ 50.00 (V)
Caution
Since the weld time varies according to the head moving time even under the same welding
conditions in the auto mode (including the fine weld mode), Interval of acquisition and Number of
waveform data also vary.