![Amada PULSETIG MAWA-050A Operation Manual Download Page 58](http://html1.mh-extra.com/html/amada/pulsetig-mawa-050a/pulsetig-mawa-050a_operation-manual_2915804058.webp)
MAWA-050A
2. Installation and Connections
2-26
(3) -2-3. Option input/output connector (D-Sub 25-pin, male)
Option input/output signals
D-Sub 25(Male)
H-COM
INT.24V
EXT.COM
1) H-ST1
INT.24V
2) H-COM
8) H-COM
3) H-READY
6) H-ST2
4) GAS
5) MID POINT
7) H-ERROR
9) H-OUT_COM
21
2
8
23
1
6
3
4
5
7
10
11
12
13
14
22
15
17
16
18
19
20
9
24
25
I/O HEAD (OPTION)
10) H-END
11) H-ORG
12) H-RESET
14) H-HEAD UP
22) H-MODE
16) H-STOP
17) H-STOP_COM
20) H-CY VLV
21) H-CY VLV_COM
15) H-OUT_COM
23) EXT_COM2
24) 0V
25) INT.24V
13) M-READY
H-COM
H-ST1
H-ST2
H-READY
GAS
MID POINT
H-ERROR
H-OUT_COM
H-OUT_COM
0V
24V
EXT_COM2
H-END
H-ORG
H-RESET
M-READY
H-HEAD UP
H-MODE
H-STOP_COM
H-STOP
H-CY VLV
H-CY VLV_COM
TORCH SELECT
TORCH SELECT_COM
18) TORCH SELECT
19) TORCH SELECT_COM
* When the internal power supply is used, connect terminal No.23 and terminal No.25.
When the external power supply is used, connect 24 V DC to terminal No.23 and 0 V to terminal
No.24.
*