MAWA-050A
5. Welding
5-18
(7)
Preparation for Starting Welding
The preparation to be made before a start of welding will be described below.
To perform welding, display the Monitor screen on the touch panel display.
Remarks
When the Monitor screen is displayed, welding is enabled and the READY signal is output.
The conditions that the READY signal is not output are as follows.
- When an error occurs.
- During the welding sequence.
- When the START input (operation panel and external input) is closed.
- The WELD STOP of the external input is closed.
- The SCH signal is not input when “4. (6)
(c) SCH & Torch select by I/O” is set to ON.
Displaying the Monitor screen
1. Press MONITOR in the upper right part of the
screen.
The Monitor screen is displayed.
2. Make sure that condition No. in which welding
conditions are set is set in the “SCH No” item on
the Monitor screen. To select SCH by external
I/O, this display is updated after the end of
welding.