![Amada PULSETIG MAWA-050A Operation Manual Download Page 163](http://html1.mh-extra.com/html/amada/pulsetig-mawa-050a/pulsetig-mawa-050a_operation-manual_2915804163.webp)
MAWA-050A
7. External Communication Function
7-11
Command 06 (basic setting data) Common data (Condition No.: fixed to 000)
Item Contents
Character
string
Range
1 (*1)
Power supply model
nnnnnnnnn, MAWA-050A
2 (*1)
CPU software version Vnn-nnn,
V**-***
3 (*1)
GP panel software version
Vnn-nnn,
V**-***
4 (*1)
Stat mode
n,
1: Touch start
2: High-voltage start
5 (*1)
Device No.
nn,
01 ~ 31
6 (*1)
External communication type
n,
0: OFF (External communication is
not performed.)
1: One-way communication
2: Two-way communication
7 (*1)
External communication speed
n,
0: 9600 1: 14400
2: 19200 3: 38400
8 (*1)
Internal resistance
n,
0: OFF 1: ON
9 Language
selection
n,
1: Japanese 2: English
3: Korean
4: Chinese (simplified characters)
5: German
10
Panel brightness adjustment
nn,
01 ~ 15 (15 is the brightest.)
11
NG judgment error
n,
0: OFF 1: ON
12
Start parity error ON/OFF
n,
0: OFF 1: ON
13
SCH & Torch select by I/O
n,
0: OFF 1: ON
14
Measurement current select
n,
1: PEAK 2: RMS
15
Measurement voltage select
n,
1: PEAK 2: RMS
16
Enable START Switch
n,
0: OFF 1: ON
17
Internal Gas Flow
n,
0: OFF 1: ON
18
High speed SCH change
n, 0:
OFF
1:
ON
19
Fine Weld Mode
n,
0: OFF 1: ON
20
Torch driving type
n,
1: MOTOR 2: CYLINDER
21
WELD ON
n,
0: OFF 1: ON
22
GOOD/NG signal output time
nnn,
001 ~ 200 (ms)
23
END signal output time
nnn,
001 ~ 200 (ms)
24
START signal input decision delay
time
nnn,
001 ~ 200 (ms)
25
SCH changeover delay time
nnn,
001 ~ 200 (ms)
26
TORCH changeover delay time
nnn,
001 ~ 200 (ms)
27
H-END
nnn,
001 ~ 200 (ms)