MAWA-050A
2. Installation and Connections
2-23
(3) -1-4. Current/voltage monitor connector (D-Sub 15-pin, female)
Remarks
Output terminals are output by isolation amplifier.
For connecting to the monitor connector, use D-Sub connector high-density 15-pin, male.
Recommended
parts
Connector
HD-15SP (MISUMI Corporation)
Case
MDA-9H-M2.6 (MISUMI Corporation)
Current/voltage monitor
Terminal No. Terminal name
Explanation
1
I
Welding current analog signal (*1)
2
I.COM
Welding current analog signal common
3
V
Welding voltage analog signal (*2)
4
V.COM
Welding voltage analog signal common
*1: When the welding current value is 50 A, a voltage of approx. 3.8 V is output.
*2: When the welding voltage value is 51.2 V, a voltage of approx. 5 V is output.