MAWA-050A
5. Welding
5-6
(4) -2. Welding current pulse modulation setting
The welding current pulse modulation setting will be described below.
Perform this welding current pulse modulation setting on the Schedule setting screen.
Remarks
The welding current is determined from the set data on the Welding condition setting screen and
the set data on the Schedule setting screen.
The Schedule setting screen consists of 2 pages.
- Schedule setting screen (1/2): The first welding pulse modulation can be set.
- Schedule setting screen (2/2): The second welding pulse modulation can be set.
Displaying the Schedule setting screen
1. Press
on the Welding condition setting
screen.
The Schedule setting screen (1/2) is displayed.
For the details of the Schedule setting screen (1/2),
refer to “4. (10)
Schedule setting screen (1/2).”
The Schedule setting screen (2/2) is displayed by
pressing
on the Schedule setting screen
(1/2).
For the details of the Schedule setting screen (2/2),
refer to “4. (10)
Schedule setting screen (2/2).”