MAWA-050A
4. Explanation of Screens
4-44
Screen Parameter
Initial
value
Welding
condition
setting screen
(all of
conditions Nos.
1 ~ 127)
SCH No. (condition No.)
1
TORCH 1
SCH TYPE CHG (condition setting mode)
FULL
FST (current value)
5.00 [A]
UF1 (current value)
5.00 [A]
UL1 (current value)
5.00 [A]
PL1 (current value)
5.00 [A]
DF1 (current value)
5.00 [A]
DL1 (current value)
5.00 [A]
COL (current value)
5.00 [A]
UF2 (current value)
5.00 [A]
UL2 (current value)
5.00 [A]
PL2 (current value)
5.00 [A]
DF2 (current value)
5.00 [A]
DL2 (current value)
5.00 [A]
PRE (time)
0 [ms]
FST (time)
0.0 [ms]
UPS1 (time)
0.0 [ms]
WEL1 (time)
0.0 [ms]
DWS1 (time)
0.0 [ms]
COL (time)
0 [ms]
UPS2 (time)
0.0 [ms]
WEL2 (time)
0.0 [ms]
DWS2 (time)
0.0 [ms]
AFT (time)
0 [ms]
Schedule
setting screen
(all of condition
Nos. 1 ~ 127)
Weld1 welding pulse modulation ON/OFF
OFF
Weld1 welding frequency [Hz]
1 [Hz]
Weld1 welding duty ratio [%]
50 [%]
Weld1 up/down pulse modulation ON/OFF
OFF
Weld1 base current [A]
5.00 [A]
Weld2 welding pulse modulation ON/OFF
OFF
Weld2 welding frequency [Hz]
1 [Hz]
Weld2 welding duty ratio [%]
50 [%]
Weld2 up/down pulse modulation ON/OFF
OFF
Weld2 base current [A]
5.00 [A]