MAWA-050A
4. Explanation of Screens
4-23
(9)
Welding Condition Setting Screen
This welding power supply permits setting up to 127 types of welding condition.
In this screen, the welding condition No., weld time length, welding current magnitude, etc. are set.
There are two setting screens, namely, FULL SETTING screen in which all the detail condition
settings can be set by operator himself and SIMPLE SETTING screen in which conditions can be
input easily.
FULL SETTING screen
*1 Settable time is [WELD1 section set time] + [COL set time] + [WELD2 section set
time]
≤
4000 [ms]. (The total set time in a red frame cannot be over 4000 ms.)
(a) SCH No.
Select a welding condition to be set among Nos. 1 ~ 127. Usually, select No. from 1
in order.
When the “SCH & Torch select by I/O” item of the Switch select screen (1/2) is set to
“OFF”, the condition No. to be used for welding is equal to the condition No. that is set
here.
WELD 1 section
WELD 2 section
*1 Welding settable time
≤
4000 ms