
MAWA-050A
4. Explanation of Screens
4-34
Copy data check screen
This screen is used to check the copy source data and copy destination data.
It is possible to check the current, time and upper/lower limit value of an optional condition No.
(f) SCH
The condition No. of the displayed data is displayed.
(g) WELD1 data display area
The WELD1 (first welding) data is displayed.
(h) WELD2 data display area
The WELD2 (second welding) data is displayed.
Items of WELD1/WELD2 data display area
FST
Initial current/initial current time
UF1, UF2
Up-slope initial current/up-slope time
UL1, UL2
Up-slope final current
PL1, PL2
Pulse current/main welding time
DF1, DF2
Down-slope initial current/down-slope time
DL1, DL2
Down-slope final current
BASE1, BASE2 Modulation base current
COL
Cooling in-time current
CURR UP
Current upper limit value
CURR DN
Current lower limit value
VOLT UP
Voltage upper limit value
VOLT DN
Voltage lower limit value
TIME UP
Time upper limit value
TIME DN
Time lower limit value
(i) BACK
The SCH copy screen reappears.