Chapter
11
93
ML-9011A
11.2 Extended External Input and Output (EEXT. I/O)
11.2.2 Connection Examples
■
When connected to an output PLC with a 24 V DC source
Internal
External
13
14
24 V DC
Load
2, 3, 4, 5, 6, 7, 8, 9,
10, 11, 12
DI
1
10k
10k
TLP290-4
15
+24V
TLP176G
0V