Chapter
7
35
ML-9011A
7.1 Turning the Hardware On and Off
6
On the Control Unit, turn on the Control
keyswitch.
LD operations are now possible, and the
icon is displayed. The [Key Switch]
indicator on the marking screen is lit in
green.
7
Confirm the following points on the marking screen:
・
The [Emergency Stop] indicator is not on.
・
The [Interlock] indicator is not lit.
・
No errors have occurred.
8
Select [Marker]-[Start LD] or click
the
icon.
The LD will now begin to start up.
A message indicating "Preparing to turn
on LD" is displayed. After the LD starts
up, the [Start LD] indicator on the
marking screen turns green.
[Key Switch] indicator