
Chapter
11
96
ML-9011A
Chapter
11
Interface Specifications
11.2.3 Time Chart
■
During normal operations
*1
The start number setting range is 1-1023. Specifying “0” is regarded as equivalent to specifying
“1.”
*2 Start numbers are acquired at the rising edge of start number confirmation strobe input, and
confirmed when the start number confirmation output turns ON. Do not change the conditions of
the start number input until the start number confirmation output is ON.
Start number confirmation strobe input is valid while startup ready is ON and marking in
progress is OFF.
*3 Marking start input is valid while marking ready output is ON and remote status output is ON.
*4 Local/remote switching can be specified from a computer or device connected via RS-232C.
End of Marking
Start of Marking
LD ON
*2
Local
Remote
*4
*3
*1
Marking start
input
Marking in progress
output
Marking ready
output
Startup ready
output
Laser start
input
LD ON
output
Remote status
output
Start no. confirmation
Output
Start no. confirmation
Strobe input
Start no.
input
Start no.
confirmation
Start no.
confirmation
Local/remote
switching input
min 0 ms