Chapter
8
42
ML-9011A
Chapter
8
Marker Specifications
8.2 Marking Area Specifications
f
lens
f80 (telecentric)
f100
f160
f163 (telecentric)
Scanning method
Galvanometer scanner
Marking area
*2*3
49 mm
49 mm
43 mm
43 mm
φ
80 mm
φ
70 mm
98 mm
98 mm
96 mm
96 mm
74 mm
74 mm
71 mm
71 mm
Work distance
74±2
mm
95
±2
mm
17
6±4
mm
1
95±4
mm
Position resolution
*1
1
µm
2
µm
2
µm
2
µm
Marking speed
(mm/s)
*2*3
0.01-5,000
0.01-2,500
0.01-7,000
0.01-3,100
0.01-11,000
0.01-5,000
0.01-10,000
0.01-5,000
f
lens
f254
f300
f410
Scanning method
Galvanometer scanner
Marking area
*2*3
141 mm
141 mm
134 mm
134 mm
175 mm
175 mm
155 mm
155 mm
216 mm
216 mm
209 mm
209 mm
Work distance
2
82±6
mm
32
4±7
mm
4
27±9
mm
Position resolution
*1
3
µm
4
µm
4
µm
Marking speed
(mm/s)
*2*3
0.01-17,000
0.01-7,900
0.01-20,000
0.01-9,300
0.01-27,000
0.01-12,800
*1 Computated value. Not the actual position accuracy.
*2 The upper column denotes values for analog scanners, and the lower column denotes values for digital
scanners.
*3 Computated value. Confirm the appropriate speed for marking during actual marking operations.