11.1 External Input and Output (EXT. I/O)
■
If the counter is used (Count reset and count up enabled)
*9 Marking stops after the final value on the counter is marked, and both the count-up output and
data error output switch on.
*10 Turn OFF counter reset input before marking start input. Additionally, do not turn ON counter
reset input while marking is in progress.
*11 When error reset input switches on, data error output switches off, and marking ready output
switches on.
Marking stops after the final value on the counter is marked. Depending on the layout
marking order, some marking data may not be marked.