Chapter
8
41
ML-9011A
8.1 Basic Specifications
Environment
Voltage fluctuation and
frequency fluctuation
Voltage
±
10%; Frequency
±
3 Hz
Oil mist, dust
0.1 mg/m
3
max.
Marking
Typefaces
TrueType/OpenType fonts, DIN, JIS Z 8905, JIS Z 8904, JIS Z
8903, OCR-A, OCR-B, and Roundhand font
Supported characters
Letters (uppercase and lowercase), numbers, and symbols
Supported file formats
DXF (AutoCAD 2009 DXF format), BMP, JPEG, GIF, and TIFF
Barcode types
Barcode 39, ITF, and Code 128
2D code types
DataMatrix (rectangular and square), GS1 DataMatrix, QR
Code, and Micro QR Code
*1 The required power supply is as follows: single-phase 100 V AC to 120 V AC (50/60 Hz) with a capacity
of at least 15 A, or 200 V AC to 240 V AC (50/60 Hz) with a capacity of at least 7 A.
*2 Be sure to ground the unit with a Class D ground.
*3 The operation environment specification range is as shown below. Condensation may occur in the
“Exclusion” part. Also, use the unit in a place where
a sudden temperature change does not occur.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
5°C
10°C
15°C
20°C
25°C
30°C
35°C
Temperature
Humid
Exclusion
Operation environment
specification range