Chapter
9
60
ML-9011A
Chapter
9
Serial Interface Specifications
(18) DMR/DMW (Number of cells of DataMatrix, Cell part setting)
Obtain (read) the number of cells of DataMatrix and cell part information.
Also used to write for arbitrary number of cells of DataMatrix and cell part.
■
Read (DMR)
s0:
“Number of cells” number
s1: L shape symbol part number
s2: Cell part number
s3: Margin part number
■
Write (DMW t0,t1,t2,t3)
t0:
“Number of cells” number
(0 - 30)
t1:
L shape symbol part number (0 - 65535)
t2:
Cell part number (1 - 65535)
t3:
Margin part number (1 - 65535)
[How to register the part No.]
Computer ->
Marker
: DMR
Marker ->
Computer
: S0, S1, S2, S3
Example
When setting the number of cells of DataMatrix
to “8 × 32”, the L shape symbol part number to “none”,
the cell part number to “20002”, and the margin part number to “20003.”
Marker ->
Computer
: DMW26,0,20002,20003
Value
Number
of Cells
Value Number
of Cells
Value
Number
of Cells
Value
Number
of Cells
0
Auto
8
24
×
24
16
64
×
64
24
144
×
144
1
10
×
10
9
26
×
26
17
72
×
72
25
8
×
18
2
12
×
12
10
32
×
32
18
80
×
80
26
8
×
32
3
14
×
14
11
36
×
36
19
88
×
88
27
12
×
26
4
16
×
16
12
40
×
40
20
96
×
96
28
12
×
36
5
18
×
18
13
44
×
44
21
104
×
104
29
16
×
36
6
20
×
20
14
48
×
48
22
120
×
120
30
16
×
48
7
22
×
22
15
52
×
52
23
132
×
132
・
When 0 is specified for the number of cells, it is automatically set.
・
ECC is fixed to 200.
・
Since the setting is stored in the memory card, it is effective even if the power
supply is turned off.
・
When the value out of the range is specified, NAK is returned.
・
When 0 is specified for the L shape symbol part number, no part is set.
・
For the part number specified for the L shape symbol, cell and margin parts, get it
by part filename with GNS command.
・
DMW command can be used only in the DataMatrix
setting with the “Default” check
box on the barcode setting dialog box selected. For details, refer to the Operations
manual.