Chapter
9
57
ML-9011A
9.5 Commands
(17) MRR/MRW (Marking data)
Obtain (read) the value of the existing layout number and specified line or change (write) the
settings.
■
Read (MRR s0, s1)
s0: Layout number
s1: Line no.
■
Read array data (MRR s0, 1, 5, s3)
s0: Layout number
s3: Array no. (More than one can be specified)
■
Write (MRW t0, t1, tn...)
t0:
Layout number
t1:
Line no.
tn:
Marking data information
Example
When changing the character string of variable data No. 2 to ABC in the first standard, and the
character string of variable data No. 5 to 0123 in the second standard
Computer ->
Marker
: VCW2,0,ABC,5,1,0123
Characters conforming to VDW parameters are supported.
Example
When obtaining the value of layout #1 and line #1
Computer ->
Marker
: MRR1, 1
Marker ->
Computer
: 2, 0, 0, , , , , , , , , 1000, , , , , , , , , , 0, ABCD
Alignment = Linear, Marking Coordinate = (0, 0), Character Height = 1 mm,
ABCD in the 1st standard font (see the table on the next page for data
arrangement)
Example
When obtaining the value of layout #1 and arrays 1, 2, and 10
Computer ->
Marker
: MRR1, 1, 5, 1, 2, 10
Marker ->
Computer
: 10000,0,45000001,20000,0,0,20000,20000,0
Matrix No. 1:
X offset 10.000mm, Y offset 0.000mm, Axis rotation angle 45.000001
°
Matrix No. 2:
X offset 20.000mm, Y offset 0.000mm, Axis rotation angle 0.000000
°
Matrix No. 10:
X offset 20.000mm, Y offset 20.000mm, Axis rotation angle 0.000000
°
When variable data including a cell set number is edited with VDW or VCW
command, the cell set number is remained unchanged. However, when the
character type is changed to anything other than special characters, the cell set
number setting is deleted.