Chapter
9
53
ML-9011A
9.5 Commands
■
Command Details
(1) CUR/CUW (Current)
Read/Write the LD current set on the system.
The setting increment is 0.1%.
(2) LOR/LOW (Current offset)
Read/Write the LD current offset set on the system.
The setting increment is 1%.
(3) SPR/SPW (Marking speed)
Read/Write the marking speed set on the system.
The setting increment is 0.01 mm/s.
(4) PUR/PUW (QSW Frequency)
Read/Write the QSW frequency set on the system.
The setting increment is 0.1 kHz.
(5) RTR/RTW (Axial rotation angle)
Read/Write the axial rotation angle at which all layout data is rotated.
The setting increment is 0.000001°.
(6) XOR/XOW (X-axis offset)
Read/Write the X-axis offset for all the layout data.
The setting increment is 1 µm.
(7) YOR/YOW (Y-axis offset)
Read/Write the Y-axis offset for all layout data.
The setting increment is 1 µm.
GRS
Marking data
Part binary registration
SVL
Layout save to memory
card
SVG
Part save to memory
card
SVV
Variable save to
memory card
ERR
Maintenance
Reset errors
TRB
Error code acquisition
COR
COW
Status
Auto transmission
0: OFF
1: ON
ACR
ACW
Elapsed time for
consumables
1 second
BAR
BAW
Transmission
conditions
WSR
WSW
Warm up scanner
-
Command
Function details
Read
Write
Parameter
Setting increment/
details