W
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
3rd
LO
[
]
(:DIAG:SERV:IF:TLOC:MODE
{AUTO|AC|DC}
)
Displays
the
control
menu
that
allows
you
to
control
the
3rd
LO
(third
local
oscillator)
in
the
A6
receiver
IF
.
The
softkeys
in
this
control
menu
are
described
below
.
The
abbreviation
of
the
current
setting
is
displayed
in
the
brackets
of
the
menu.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
3rd
LO:
AUTO
sets
the
3rd
LO
control
to
the
automatic
mode
(normal
operation).
In
this
mode
,
the
analyzer
controls
the
3rd
LO
automatically
according
to
the
measurement
settings
.
NNNNNNNN
AC
sets
the
3rd
LO
to
the
A
C
sampling
mode
.
In
this
mode
,
the
3rd
LO
generates
85.6
MHz.
NNNNNNNN
DC
sets
the
3rd
LO
to
the
DC
sampling
mode
.
In
this
mode
,
the
3rd
LO
generates
85.68
MHz.
W
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
IF
BPF
[
]
(:DIAG:SERV:IF:BPF:MODE
{AUTO|BW3M|BW1M|XTAL}
)
Displays
the
control
menu
that
allows
you
to
select
one
of
the
IF
BPFs
(IF
band
pass
lters)
in
the
A6
receiver
IF
.
The
2nd
IF
goes
through
the
selected
BPF
to
the
3rd
IF
converter
.
The
softkeys
in
this
control
menu
are
described
below
.
The
abbreviation
of
the
selected
BPF
is
displayed
in
the
brackets
of
the
menu.
N
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
IF
BPF:
AUTO
sets
the
IF
BPF
control
to
automatic
mode
(normal
operation).
In
this
mode
,
the
analyzer
sets
the
IF
BPF
setting
to
the
3
MHz,
1
MHz,
or
crystal
IF
BPFs
automatically
according
to
the
measurement
setting.
NNNNNNNN
3M
selects
the
3
MHz
BPF
in
the
IF
BPFs
.
NNNNNNNN
1M
selects
the
1
MHz
BPF
in
the
IF
BPFs
.
NNNNNNNNNNNNNN
XTAL
selects
the
10
kHz
crystal
BPF
in
the
IF
BPFs
.
W
WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW
IF
GAIN
[
]
Displays
the
control
menus
that
allow
you
to
control
the
IF
gains
W
,
X,
Y
and
Z
in
the
A6
receiver
IF
.
The
softkeys
in
these
control
menus
are
described
below
.
The
abbreviation
of
the
current
setting
(A
UTO
or
MANU
AL)
is
displayed
in
the
brackets
of
the
menu.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
IF
GAIN
AUTO
man
(:DIAG:SERV:IF:GAIN:MODE
{AUTO|MAN} )
T
oggles
the
IF
gain
control
mode
to
automatic
mode
(normal
operation)
or
manual
mode
.
In
the
automatic
mode
,
the
analyzer
controls
the
IF
gain
W
,
X,
Y
,
and
Z
settings
automatically
according
to
the
measurement
setting.
In
the
manual
mode
,
the
IF
gains
are
controlled
by
the
following
softkeys
.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
GAIN
W
[
]
(:DIAG:SERV:IF:GAIN:W
{AUTO|DB0|DB10} )
Displays
the
control
menu
for
the
IF
GAIN
W
.
The
softkeys
in
this
control
menu
are
described
below
.
The
abbreviation
of
the
current
setting
(A
UTO
,
0
dB
,
or
10
dB)
is
displayed
in
the
brackets
of
the
menu.
NNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNNN
GAIN
W:
AUTO
sets
the
IF
GAIN
W
setting
to
automatic
mode
.
NNNNNNNNNNNNNN
0
dB
sets
the
IF
GAIN
W
to
0
dB
.
NNNNNNNNNNNNNNNNN
10
dB
sets
the
IF
GAIN
W
to
10
dB
.
10-36
Service
K
ey
Menus
Summary of Contents for Agilent 4396B
Page 10: ......
Page 32: ......
Page 43: ...Figure 2 7 CAL OUT Level Adjustment Location Adjustments and Correction Constants 2 11 ...
Page 46: ...Figure 2 10 Comb Generator Output 2 14 Adjustments and Correction Constants ...
Page 62: ...Figure 2 26 Final Gain Adjustment Location 2 30 Adjustments and Correction Constants ...
Page 76: ...Figure 3 1 Troubleshooting Organization 3 2 T roubleshooting ...
Page 84: ......
Page 90: ...Figure 5 1 Power Supply Lines Simpli ed Block Diagram 5 2 Power Supply T roubleshooting ...
Page 107: ...Figure 5 12 Power Supply Block Diagram 1 Power Supply T roubleshooting 5 19 ...
Page 108: ...Figure 5 13 Power Supply Block Diagram 2 5 20 Power Supply T roubleshooting ...
Page 109: ...Figure 5 14 Power Supply Block Diagram 3 Power Supply T roubleshooting 5 21 ...
Page 110: ......
Page 112: ...Figure 6 1 Digital Control Group Simpli ed Block Diagram 6 2 Digital Control T roubleshooting ...
Page 124: ......
Page 126: ...Figure 7 1 Source Group Block Diagram 7 2 Source Group T roubleshooting ...
Page 160: ...Figure 8 1 Receiver Group Simpli ed Block Diagram 8 2 Receiver Group T roubleshooting ...
Page 168: ......
Page 184: ...Figure 10 6 External Test Setup 1 Figure 10 7 External Test Setup 2 10 10 Service Key Menus ...
Page 185: ...Figure 10 8 External Test Setup 3 Figure 10 9 External Test Setup 4 Service Key Menus 10 11 ...
Page 226: ...Figure 11 3 Power Supply Functional Group Simpli ed Block Diagram 11 6 Theory of Operation ...
Page 231: ...Figure 11 5 Digital Control Group Simpli ed Block Diagram Theory of Operation 11 11 ...
Page 235: ...Figure 11 6 Source Simpli ed Block Diagram Theory of Operation 11 15 ...
Page 244: ...Figure 11 7 Receiver Simpli ed Block Diagram 11 24 Theory of Operation ...
Page 249: ...Figure IDC5S11001 here Figure 11 8 4396B Source Group Block Diagram Theory of Operation 11 29 ...
Page 254: ...Figure 12 1 Top View Major Assemblies 12 4 Replaceable Parts ...
Page 290: ...Figure 12 36 Main Frame Assembly Parts 17 19 12 40 Replaceable Parts ...
Page 294: ......
Page 308: ......
Page 311: ...Figure C 1 Power Cable Supplied Power Requirement C 3 ...
Page 312: ......
Page 324: ......